{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/towards-resilient-and-secure-smart-grids","title":"Towards Resilient and Secure Smart Grids against PMU Adversarial Attacks: A Deep Learning-Based Robust Data Engineering Approach","arxiv_id":null,"date":"2023-06-06","proceeding":"MDPI Electronics 2023 6","authors":["Tarek Berghout","Mohamed Benbouzid","Yassine Amirat"],"abstract":"In an attempt to provide reliable power distribution, smart grids integrate monitoring, communication, and control technologies for better energy consumption and management. As a result of such cyberphysical links, smart grids become vulnerable to cyberattacks, highlighting the significance of detecting and monitoring such attacks to uphold their security and dependability. Accordingly, the use of phasor measurement units (PMUs) enables real-time monitoring and control, providing informed-decisions data and making it possible to sense abnormal behavior indicative of cyberattacks. Similar to the ways it dominates other fields, deep learning has brought a lot of interest to the realm of cybersecurity. A common formulation for this issue is learning under data complexity, unavailability, and drift connected to increasing cardinality, imbalance brought on by data scarcity, and fast change in data characteristics, respectively. To address these challenges, this paper suggests a deep learning monitoring method based on robust feature engineering, using PMU data with greater accuracy, even within the presence of cyberattacks. The model is initially investigated using condition monitoring data to identify various disturbances in smart grids free from adversarial attacks. Then, a minimally disruptive experiment using adversarial attack injection with various reality-imitating techniques is conducted, inadvertently damaging the original data and using it to retrain the deep network, boosting its resistance to manipulations. Compared to previous studies, the proposed method demonstrated promising results and better accuracy, making it a potential option for smart grid condition monitoring. The full set of experimental scenarios performed in this study is available online.","url_abs":"https://www.mdpi.com/2079-9292/12/12/2554","url_pdf":"https://www.mdpi.com/2079-9292/12/12/2554","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"towards-resilient-and-secure-smart-grids","repo_url":"https://github.com/TBdevellopper/Mitigation-of-adversarial-attacks-monitoring-smart-grids","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"none","reach":null}],"tasks":[{"task_slug":"adversarial-attack","task_name":"Adversarial Attack"},{"task_slug":"color-image-denoising","task_name":"Color Image Denoising"},{"task_slug":"feature-engineering","task_name":"Feature Engineering"},{"task_slug":"image-segmentation","task_name":"Image Segmentation"}],"methods":[{"method_slug":"lstm","method_name":"LSTM"},{"method_slug":"sigmoid-activation","method_name":"Sigmoid Activation"},{"method_slug":"tanh-activation","method_name":"Tanh Activation"},{"method_slug":null,"method_name":"Uphold"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[{"repo":"TBdevellopper/Mitigation-of-adversarial-attacks-monitoring-smart-grids","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"ee367dbc1647df0c2bd7f9504ca286cfdb1d30423dcafb694d43a5d1d8397f5f","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}