{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/towards-better-heartbeat-segmentation-with","title":"Towards better heartbeat segmentation with deep learning classification","arxiv_id":null,"date":"2020-11-26","proceeding":null,"authors":["Pedro Silva","Eduardo Luz","Guilherme Silva","Gladston Moreira"],"abstract":"The confidence of medical equipment is intimately related to false alarms. The higher the number of false events occurs, the less truthful is the equipment. In this sense, reducing (or suppressing) false positive alarms is hugely desirable. In this work, we propose a feasible and real-time approach that works as a validation method for a heartbeat segmentation third-party algorithm. The approach is based on convolutional neural networks (CNNs), which may be embedded in dedicated hardware. Our proposal aims to detect the pattern of a single heartbeat and classifies them into two classes: a heartbeat and not a heartbeat. For this, a seven-layer convolution network is employed for both data representation and classification. We evaluate our approach in two well-settled databases in the literature on the raw heartbeat signal. The first database is a conventional on-the-person database called MIT-BIH, and the second is one less uncontrolled off-the-person type database known as CYBHi. To evaluate the feasibility and the performance of the proposed approach, we use as a baseline the Pam-Tompkins algorithm, which is a well-known method in the literature and still used in the industry. We compare the baseline against the proposed approach: a CNN model validating the heartbeats detected by a third-party algorithm. In this work, the third-party algorithm is the same as the baseline for comparison purposes. The results support the feasibility of our approach showing that our method can enhance the positive prediction of the Pan-Tompkins algorithm from 97.84%/90.28% to 100.00%/96.77% by slightly decreasing the sensitivity from 95.79%/96.95% to 92.98%/ 95.71% on the MIT-BIH/CYBHi databases.","url_abs":"https://www.nature.com/articles/s41598-020-77745-0","url_pdf":"https://www.nature.com/articles/s41598-020-77745-0","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"towards-better-heartbeat-segmentation-with","repo_url":"https://github.com/ufopcsilab/qrs-better-heartbeat-segmentation","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"none","reach":null}],"tasks":[{"task_slug":"classification-1","task_name":"Classification"},{"task_slug":"deep-learning","task_name":"Deep Learning"},{"task_slug":"classification","task_name":"General Classification"}],"methods":[{"method_slug":"convolution","method_name":"Convolution"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[{"repo":"ufopcsilab/qrs-better-heartbeat-segmentation","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"a8280a5ed28f6582badca6e6bb4ed9aaf9a96429024efc4a8d86c958c7363071","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}