{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/tecno-surgical-phase-recognition-with-multi","title":"TeCNO: Surgical Phase Recognition with Multi-Stage Temporal Convolutional Networks","arxiv_id":"2003.10751","date":"2020-03-24","proceeding":null,"authors":["Tobias Czempiel","Magdalini Paschali","Matthias Keicher","Walter Simson","Hubertus Feussner","Seong Tae Kim","Nassir Navab"],"abstract":"Automatic surgical phase recognition is a challenging and crucial task with the potential to improve patient safety and become an integral part of intra-operative decision-support systems. In this paper, we propose, for the first time in workflow analysis, a Multi-Stage Temporal Convolutional Network (MS-TCN) that performs hierarchical prediction refinement for surgical phase recognition. Causal, dilated convolutions allow for a large receptive field and online inference with smooth predictions even during ambiguous transitions. Our method is thoroughly evaluated on two datasets of laparoscopic cholecystectomy videos with and without the use of additional surgical tool information. Outperforming various state-of-the-art LSTM approaches, we verify the suitability of the proposed causal MS-TCN for surgical phase recognition.","url_abs":"https://arxiv.org/abs/2003.10751v1","url_pdf":"https://arxiv.org/pdf/2003.10751v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"tecno-surgical-phase-recognition-with-multi","repo_url":"https://github.com/tobiascz/TeCNO","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":null},{"paper_slug":"tecno-surgical-phase-recognition-with-multi","repo_url":"https://github.com/xjgaocs/Trans-SVNet","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"surgical-phase-recognition","task_name":"Surgical phase recognition"}],"methods":[{"method_slug":"1x1-convolution","method_name":"1x1 Convolution"},{"method_slug":"lstm","method_name":"LSTM"},{"method_slug":"sigmoid-activation","method_name":"Sigmoid Activation"},{"method_slug":"tanh-activation","method_name":"Tanh Activation"}],"datasets_introduced":[],"methods_introduced":[],"results":[{"leaderboard":"/sota/surgical-phase-recognition-on-cholec80-1","task":"Surgical phase recognition","dataset":"Cholec80","model":"TCN","rank_in_archive_order":5,"of":6,"metrics":{"F1":"80.3"},"uses_additional_data":false}],"syntology":{"syntology_url":"https://syntology.ai/paper/2003.10751","atlas_url":"https://app.syntology.ai/?focus=2003.10751","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2003.10751"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2003.10751\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2003.10751"},"call":"get_concepts_for_paper(arxiv_id=\"2003.10751\")"}],"by_repo":[{"repo":"tobiascz/TeCNO","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"xjgaocs/Trans-SVNet","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"1603fc84cdac718e58631f1bdbda05c7750020b69c5df108df72e5dac615141a","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}