{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/technical-report-quality-assessment-tool-for","title":"Technical Report: Quality Assessment Tool for Machine Learning with Clinical CT","arxiv_id":"2107.12842","date":"2021-07-27","proceeding":null,"authors":["Riqiang Gao","Mirza S. Khan","Yucheng Tang","Kaiwen Xu","Steve Deppen","Yuankai Huo","Kim L. Sandler","Pierre P. Massion","Bennett A. Landman"],"abstract":"Image Quality Assessment (IQA) is important for scientific inquiry, especially in medical imaging and machine learning. Potential data quality issues can be exacerbated when human-based workflows use limited views of the data that may obscure digital artifacts. In practice, multiple factors such as network issues, accelerated acquisitions, motion artifacts, and imaging protocol design can impede the interpretation of image collections. The medical image processing community has developed a wide variety of tools for the inspection and validation of imaging data. Yet, IQA of computed tomography (CT) remains an under-recognized challenge, and no user-friendly tool is commonly available to address these potential issues. Here, we create and illustrate a pipeline specifically designed to identify and resolve issues encountered with large-scale data mining of clinically acquired CT data. Using the widely studied National Lung Screening Trial (NLST), we have identified approximately 4% of image volumes with quality concerns out of 17,392 scans. To assess robustness, we applied the proposed pipeline to our internal datasets where we find our tool is generalizable to clinically acquired medical images. In conclusion, the tool has been useful and time-saving for research study of clinical data, and the code and tutorials are publicly available at https://github.com/MASILab/QA_tool.","url_abs":"https://arxiv.org/abs/2107.12842v1","url_pdf":"https://arxiv.org/pdf/2107.12842v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"technical-report-quality-assessment-tool-for","repo_url":"https://github.com/MASILab/QA_tool","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"none","reach":null}],"tasks":[{"task_slug":"machine-learning","task_name":"BIG-bench Machine Learning"},{"task_slug":"computed-tomography-ct","task_name":"Computed Tomography (CT)"},{"task_slug":"image-quality-assessment","task_name":"Image Quality Assessment"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"MASILab/QA_tool","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"4694405d9b8a8bdd1ab05ae28f25aaf013874c0d90367ce34cce500877c4a517","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}