{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/systematic-assessment-of-hyperdimensional","title":"Systematic Assessment of Hyperdimensional Computing for Epileptic Seizure Detection","arxiv_id":"2105.00934","date":"2021-05-03","proceeding":null,"authors":["Una Pale","Tomas Teijeiro","David Atienza"],"abstract":"Hyperdimensional computing is a promising novel paradigm for low-power embedded machine learning. It has been applied on different biomedical applications, and particularly on epileptic seizure detection. Unfortunately, due to differences in data preparation, segmentation, encoding strategies, and performance metrics, results are hard to compare, which makes building upon that knowledge difficult. Thus, the main goal of this work is to perform a systematic assessment of the HD computing framework for the detection of epileptic seizures, comparing different feature approaches mapped to HD vectors. More precisely, we test two previously implemented features as well as several novel approaches with HD computing on epileptic seizure detection. We evaluate them in a comparable way, i.e., with the same preprocessing setup, and with the identical performance measures. We use two different datasets in order to assess the generalizability of our conclusions. The systematic assessment involved three primary aspects relevant for potential wearable implementations: 1) detection performance, 2) memory requirements, and 3) computational complexity. Our analysis shows a significant difference in detection performance between approaches, but also that the ones with the highest performance might not be ideal for wearable applications due to their high memory or computational requirements. Furthermore, we evaluate a post-processing strategy to adjust the predictions to the dynamics of epileptic seizures, showing that performance is significantly improved in all the approaches and also that after post-processing, differences in performance are much smaller between approaches.","url_abs":"https://arxiv.org/abs/2105.00934v1","url_pdf":"https://arxiv.org/pdf/2105.00934v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"systematic-assessment-of-hyperdimensional","repo_url":"https://c4science.ch/source/HDforEpilepsyPublic","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"none","reach":null}],"tasks":[{"task_slug":"seizure-detection","task_name":"Seizure Detection"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"c4science.ch/source/HDforEpilepsyPublic","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"1013a8f9254d313b4fb1ef1764f07f774f72efd89de5316a064e3718c8e3074d","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}