{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/stenunet-automatic-stenosis-detection-from-x","title":"StenUNet: Automatic Stenosis Detection from X-ray Coronary Angiography","arxiv_id":"2310.14961","date":"2023-10-23","proceeding":null,"authors":["Hui Lin","Tom Liu","Aggelos Katsaggelos","Adrienne Kline"],"abstract":"Coronary angiography continues to serve as the primary method for diagnosing coronary artery disease (CAD), which is the leading global cause of mortality. The severity of CAD is quantified by the location, degree of narrowing (stenosis), and number of arteries involved. In current practice, this quantification is performed manually using visual inspection and thus suffers from poor inter- and intra-rater reliability. The MICCAI grand challenge: Automatic Region-based Coronary Artery Disease diagnostics using the X-ray angiography imagEs (ARCADE) curated a dataset with stenosis annotations, with the goal of creating an automated stenosis detection algorithm. Using a combination of machine learning and other computer vision techniques, we propose the architecture and algorithm StenUNet to accurately detect stenosis from X-ray Coronary Angiography. Our submission to the ARCADE challenge placed 3rd among all teams. We achieved an F1 score of 0.5348 on the test set, 0.0005 lower than the 2nd place.","url_abs":"https://arxiv.org/abs/2310.14961v1","url_pdf":"https://arxiv.org/pdf/2310.14961v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"stenunet-automatic-stenosis-detection-from-x","repo_url":"https://github.com/huilin0220/stenunet","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":null},{"paper_slug":"stenunet-automatic-stenosis-detection-from-x","repo_url":"https://github.com/HuiLin0220/brighteye","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"stenosis-segmentation","task_name":"Stenosis Segmentation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"huilin0220/stenunet","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"HuiLin0220/brighteye","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"639129aacc3a50a63e303422b734f3367b2aef9e6533fff86d49abc6ed10d67b","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}