Papers › Semi-supervised Left Atrium Segmentation with Mutual Consistency Training

Semi-supervised Left Atrium Segmentation with Mutual Consistency Training

4 Mar 2021arXiv:2103.02911archive 2025-07-28

Yicheng Wu, Minfeng Xu, ZongYuan Ge, Jianfei Cai, Lei Zhang

Semi-supervised learning has attracted great attention in the field of machine learning, especially for medical image segmentation tasks, since it alleviates the heavy burden of collecting abundant densely annotated data for training. However, most of existing methods underestimate the importance of challenging regions (e.g. small branches or blurred edges) during training. We believe that these unlabeled regions may contain more crucial information to minimize the uncertainty prediction for the model and should be emphasized in the training process. Therefore, in this paper, we propose a novel Mutual Consistency Network (MC-Net) for semi-supervised left atrium segmentation from 3D MR images. Particularly, our MC-Net consists of one encoder and two slightly different decoders, and the prediction discrepancies of two decoders are transformed as an unsupervised loss by our designed cycled pseudo label scheme to encourage mutual consistency. Such mutual consistency encourages the two decoders to have consistent and low-entropy predictions and enables the model to gradually capture generalized features from these unlabeled challenging regions. We evaluate our MC-Net on the public Left Atrium (LA) database and it obtains impressive performance gains by exploiting the unlabeled data effectively. Our MC-Net outperforms six recent semi-supervised methods for left atrium segmentation, and sets the new state-of-the-art performance on the LA database.

PaperPDFCode

In Syntology View this paper on Syntology, its page in Syntology's graph. That page lists the repositories linked to the paper, the abstract and the calls for agents.

Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, on Syntology's MCP service (how to connect):

Code

HiLab-git/DTC mentioned on GitHubpytorchMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to Semi-supervised Medical Image Segmentation through Dual-task Consistency (arXiv:2009.04448; that paper's own run record: 15 ran (of which 0 constructed an object rather than computing a result; 8 with no instrument failure: 3 honoured, 1 violated, 4 with no contract checked; 7 where Syntology's instrument failed) · 3 unverified); nothing checks that they implement this paper's method. report
Luoxd1996/DTC mentioned on GitHubpytorchMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to Semi-Supervised Semantic Segmentation with Cross-Consistency Training (arXiv:2003.09005; that paper's own run record: 17 ran (of which 0 constructed an object rather than computing a result; 8 with no instrument failure: 3 honoured, 1 violated, 4 with no contract checked; 9 where Syntology's instrument failed) · 3 unverified); nothing checks that they implement this paper's method. report
yyliu01/tracoco mentioned on GitHubpytorchMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to Translation Consistent Semi-supervised Segmentation for 3D Medical Images (arXiv:2203.14523; that paper's own run record: 8 ran (of which 0 constructed an object rather than computing a result; 8 with no instrument failure: 0 honoured, 0 violated, 8 with no contract checked; 0 where Syntology's instrument failed) · 1 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Image SegmentationMedical Image SegmentationPseudo LabelSegmentationSemantic Segmentation

1 archive task tag without a task page not shown.

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections