Papers › Robust End-to-End Focal Liver Lesion Detection using Unregistered Multiphase Computed...

Robust End-to-End Focal Liver Lesion Detection using Unregistered Multiphase Computed Tomography Images

2 Dec 2021arXiv:2112.01535archive 2025-07-28

Sang-gil Lee, Eunji Kim, Jae Seok Bae, Jung Hoon Kim, Sungroh Yoon

The computer-aided diagnosis of focal liver lesions (FLLs) can help improve workflow and enable correct diagnoses; FLL detection is the first step in such a computer-aided diagnosis. Despite the recent success of deep-learning-based approaches in detecting FLLs, current methods are not sufficiently robust for assessing misaligned multiphase data. By introducing an attention-guided multiphase alignment in feature space, this study presents a fully automated, end-to-end learning framework for detecting FLLs from multiphase computed tomography (CT) images. Our method is robust to misaligned multiphase images owing to its complete learning-based approach, which reduces the sensitivity of the model's performance to the quality of registration and enables a standalone deployment of the model in clinical practice. Evaluation on a large-scale dataset with 280 patients confirmed that our method outperformed previous state-of-the-art methods and significantly reduced the performance degradation for detecting FLLs using misaligned multiphase CT images. The robustness of the proposed method can enhance the clinical adoption of the deep-learning-based computer-aided detection system.

PaperPDFCode

Syntology This paper's arXiv id is not in Syntology's Atlas id list (549,449 ids, as this build read them; the read time is in the build record), so this page links to no Syntology page for it. The list is not the whole graph; Syntology's feed shows papers as they enter the graph.

Code

andreped/livermask officialmentioned in papertfMITSyntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to The Liver Tumor Segmentation Benchmark (LiTS) (arXiv:1901.04056; that paper's own run record: 7 ran (of which 0 constructed an object rather than computing a result; 7 with no instrument failure: 0 honoured, 0 violated, 7 with no contract checked; 0 where Syntology's instrument failed) · 1 unverified); nothing checks that they implement this paper's method. report
L0SG/grouped-ssd-pytorch officialmentioned on GitHubpytorchSyntology: not harvested report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Automatic Liver And Tumor SegmentationComputed Tomography (CT)Lesion DetectionLiver SegmentationMedical Image RegistrationMedical Object DetectionObject Detection

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections