{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/rise-ieeg-robust-to-inter-subject-electrodes","title":"RISE-iEEG: Robust to Inter-Subject Electrodes Implantation Variability iEEG Classifier","arxiv_id":"2408.14477","date":"2024-08-12","proceeding":null,"authors":["Maryam Ostadsharif Memar","Navid Ziaei","Behzad Nazari","Ali Yousefi"],"abstract":"Intracranial electroencephalography (iEEG) is increasingly used for clinical and brain-computer interface applications due to its high spatial and temporal resolution. However, inter-subject variability in electrode implantation poses a challenge for developing generalized neural decoders. To address this, we introduce a novel decoder model that is robust to inter-subject electrode implantation variability. We call this model RISE-iEEG, which stands for Robust to Inter-Subject Electrode Implantation Variability iEEG Classifier. RISE-iEEG employs a deep neural network structure preceded by a participant-specific projection network. The projection network maps the neural data of individual participants onto a common low-dimensional space, compensating for the implantation variability. In other words, we developed an iEEG decoder model that can be applied across multiple participants' data without requiring the coordinates of electrode for each participant. The performance of RISE-iEEG across multiple datasets, including the Music Reconstruction dataset, and AJILE12 dataset, surpasses that of advanced iEEG decoder models such as HTNet and EEGNet. Our analysis shows that the performance of RISE-iEEG is about 7\\% higher than that of HTNet and EEGNet in terms of F1 score, with an average F1 score of 0.83, which is the highest result among the evaluation methods defined. Furthermore, Our analysis of the projection network weights reveals that the Superior Temporal and Postcentral lobes are key encoding nodes for the Music Reconstruction and AJILE12 datasets, which aligns with the primary physiological principles governing these regions. This model improves decoding accuracy while maintaining interpretability and generalization.","url_abs":"https://arxiv.org/abs/2408.14477v2","url_pdf":"https://arxiv.org/pdf/2408.14477v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"rise-ieeg-robust-to-inter-subject-electrodes","repo_url":"https://github.com/MaryamOstadsharif/RISE-iEEG","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"none","reach":null}],"tasks":[{"task_slug":"brain-computer-interface","task_name":"Brain Computer Interface"},{"task_slug":"decoder","task_name":"Decoder"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"MaryamOstadsharif/RISE-iEEG","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"0358138e9b65d6888ebe6dea5c0b83e01ed4ca7aad14af1cc1a57edb184d25d8","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}