{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/rad-a-metric-for-medical-image-distribution","title":"Fréchet Radiomic Distance (FRD): A Versatile Metric for Comparing Medical Imaging Datasets","arxiv_id":"2412.01496","date":"2024-12-02","proceeding":null,"authors":["Nicholas Konz","Richard Osuala","Preeti Verma","YuWen Chen","Hanxue Gu","Haoyu Dong","Yaqian Chen","Andrew Marshall","Lidia Garrucho","Kaisar Kushibar","Daniel M. Lang","Gene S. Kim","Lars J. Grimm","John M. Lewin","James S. Duncan","Julia A. Schnabel","Oliver Diaz","Karim Lekadir","Maciej A. Mazurowski"],"abstract":"Determining whether two sets of images belong to the same or different distributions or domains is a crucial task in modern medical image analysis and deep learning; for example, to evaluate the output quality of image generative models. Currently, metrics used for this task either rely on the (potentially biased) choice of some downstream task, such as segmentation, or adopt task-independent perceptual metrics (e.g., Fr\\'echet Inception Distance/FID) from natural imaging, which we show insufficiently capture anatomical features. To this end, we introduce a new perceptual metric tailored for medical images, FRD (Fr\\'echet Radiomic Distance), which utilizes standardized, clinically meaningful, and interpretable image features. We show that FRD is superior to other image distribution metrics for a range of medical imaging applications, including out-of-domain (OOD) detection, the evaluation of image-to-image translation (by correlating more with downstream task performance as well as anatomical consistency and realism), and the evaluation of unconditional image generation. Moreover, FRD offers additional benefits such as stability and computational efficiency at low sample sizes, sensitivity to image corruptions and adversarial attacks, feature interpretability, and correlation with radiologist-perceived image quality. Additionally, we address key gaps in the literature by presenting an extensive framework for the multifaceted evaluation of image similarity metrics in medical imaging -- including the first large-scale comparative study of generative models for medical image translation -- and release an accessible codebase to facilitate future research. Our results are supported by thorough experiments spanning a variety of datasets, modalities, and downstream tasks, highlighting the broad potential of FRD for medical image analysis.","url_abs":"https://arxiv.org/abs/2412.01496v2","url_pdf":"https://arxiv.org/pdf/2412.01496v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"rad-a-metric-for-medical-image-distribution","repo_url":"https://github.com/mazurowski-lab/medical-image-similarity-metrics","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":{"status":"ok"}},{"paper_slug":"rad-a-metric-for-medical-image-distribution","repo_url":"https://github.com/richardobi/frd-score","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"none","reach":null},{"paper_slug":"rad-a-metric-for-medical-image-distribution","repo_url":"https://github.com/mazurowski-lab/RaD","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"computational-efficiency","task_name":"Computational Efficiency"},{"task_slug":"image-generation","task_name":"Image Generation"},{"task_slug":"image-to-image-translation","task_name":"Image-to-Image Translation"},{"task_slug":"medical-image-analysis","task_name":"Medical Image Analysis"},{"task_slug":"translation","task_name":"Translation"},{"task_slug":"unconditional-image-generation","task_name":"Unconditional Image Generation"}],"methods":[{"method_slug":"adopt","method_name":"ADOPT"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2412.01496","atlas_url":"https://app.syntology.ai/?focus=2412.01496","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2412.01496"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2412.01496\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2412.01496"},"call":"get_concepts_for_paper(arxiv_id=\"2412.01496\")"}],"by_repo":[{"repo":"mazurowski-lab/medical-image-similarity-metrics","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"richardobi/frd-score","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"mazurowski-lab/RaD","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"6c20f7b040ec2203255a35f575fa1d791d7324b548f73beaef5eeb866e8592dc","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}