{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/pose-estimation-of-periacetabular-osteotomy","title":"Pose Estimation of Periacetabular Osteotomy Fragments with Intraoperative X-Ray Navigation","arxiv_id":"1903.09339","date":"2019-03-22","proceeding":null,"authors":["Robert B. Grupp","Rachel A. Hegeman","Ryan J. Murphy","Clayton P. Alexander","Yoshito Otake","Benjamin A. McArthur","Mehran Armand","Russell H. Taylor"],"abstract":"Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials. Methods: A 2D/3D registration pipeline was developed to recover fragment pose. This pipeline was tested through an extensive simulation study and 6 cadaveric surgeries. Using osteotomy boundaries in the fluoroscopic images, the preoperative plan is refined to more accurately match the intraoperative shape. Results: In simulation, average fragment pose errors were 1.3{\\deg}/1.7 mm when the planned fragment matched the intraoperative fragment, 2.2{\\deg}/2.1 mm when the plan was not updated to match the true shape, and 1.9{\\deg}/2.0 mm when the fragment shape was intraoperatively estimated. In cadaver experiments, the average pose errors were 2.2{\\deg}/2.2 mm, 3.8{\\deg}/2.5 mm, and 3.5{\\deg}/2.2 mm when registering with the actual fragment shape, a preoperative plan, and an intraoperatively refined plan, respectively. Average errors of the lateral center edge angle were less than 2{\\deg} for all fragment shapes in simulation and cadaver experiments. Conclusion: The proposed pipeline is capable of accurately reporting femoral head coverage within a range clinically identified for long-term joint survivability. Significance: Human interpretation of fragment pose is challenging and usually restricted to rotation about a single anatomical axis. The proposed pipeline provides an intraoperative estimate of rigid pose with respect to all anatomical axes, is compatible with minimally invasive incisions, and has no dependence on external fiducials.","url_abs":"https://arxiv.org/abs/1903.09339v2","url_pdf":"https://arxiv.org/pdf/1903.09339v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"pose-estimation-of-periacetabular-osteotomy","repo_url":"https://github.com/rg2/xreg","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"none","reach":{"status":"ok","spdx":"MIT"}},{"paper_slug":"pose-estimation-of-periacetabular-osteotomy","repo_url":"https://github.com/rg2/DeepFluoroLabeling-IPCAI2020","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"pytorch","reach":{"status":"ok","spdx":"NOASSERTION"}}],"tasks":[{"task_slug":"pose-estimation","task_name":"Pose Estimation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/1903.09339","atlas_url":"https://app.syntology.ai/?focus=1903.09339","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"1903.09339"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"1903.09339\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"1903.09339"},"call":"get_concepts_for_paper(arxiv_id=\"1903.09339\")"}],"by_repo":[{"repo":"rg2/xreg","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"rg2/DeepFluoroLabeling-IPCAI2020","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"c49c9842386597604cd737c89986ec007f862b3253ef86a6d8d425d54e5a6a7b","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}