{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/optimal-operation-of-a-building-with","title":"Optimal Operation of a Building with Electricity-Heat Networks and Seasonal Storage","arxiv_id":"2409.08721","date":"2024-09-13","proceeding":null,"authors":["Eléa Prat","Pierre Pinson","Richard M. Lusby","Riwal Plougonven","Jordi Badosa","Philippe Drobinski"],"abstract":"As seasonal thermal energy storage emerges as an efficient solution to reduce CO2 emissions of buildings, challenges appear related to its optimal operation. In a system including short-term electricity storage, long-term heat storage, and where electricity and heat networks are connected through a heat pump, it becomes crucial to operate the system on two time scales. Based on real data from a university building, we simulate the operation of such a system over a year, comparing different strategies based on model predictive control (MPC). The first objective of this paper is to determine the minimum prediction horizon to retrieve the results of the full-horizon operation problem with cost minimization. The second objective is to evaluate a method that combines MPC with setting targets on the heat storage level at the end of the prediction horizon, based on historical data. For a prediction horizon of 6 days, the suboptimality gap with the full-horizon results is 4.31%, compared to 11.42% when using a prediction horizon of 42 days and fixing the final level to be equal to the initial level, which is a common approach.","url_abs":"https://arxiv.org/abs/2409.08721v1","url_pdf":"https://arxiv.org/pdf/2409.08721v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"optimal-operation-of-a-building-with","repo_url":"https://github.com/eleaprat/residential-SG","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"none","reach":null}],"tasks":[{"task_slug":"model-predictive-control","task_name":"Model Predictive Control"},{"task_slug":"prediction","task_name":"Prediction"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"eleaprat/residential-SG","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"0be2ffb99229c8d4d9ffe7a3e252519a5c80d386545184e93eb00452e993fe66","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}