{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/on-the-challenges-of-detecting-mci-using-eeg","title":"On the challenges of detecting MCI using EEG in the wild","arxiv_id":"2501.17871","date":"2025-01-15","proceeding":null,"authors":["Aayush Mishra","David Joffe","Sankara Surendra Telidevara","David S Oakley","Anqi Liu"],"abstract":"Recent studies have shown promising results in the detection of Mild Cognitive Impairment (MCI) using easily accessible Electroencephalogram (EEG) data which would help administer early and effective treatment for dementia patients. However, the reliability and practicality of such systems remains unclear. In this work, we investigate the potential limitations and challenges in developing a robust MCI detection method using two contrasting datasets: 1) CAUEEG, collected and annotated by expert neurologists in controlled settings and 2) GENEEG, a new dataset collected and annotated in general practice clinics, a setting where routine MCI diagnoses are typically made. We find that training on small datasets, as is done by most previous works, tends to produce high variance models that make overconfident predictions, and are unreliable in practice. Additionally, distribution shifts between datasets make cross-domain generalization challenging. Finally, we show that MCI detection using EEG may suffer from fundamental limitations because of the overlapping nature of feature distributions with control groups. We call for more effort in high-quality data collection in actionable settings (like general practice clinics) to make progress towards this salient goal of non-invasive MCI detection.","url_abs":"https://arxiv.org/abs/2501.17871v1","url_pdf":"https://arxiv.org/pdf/2501.17871v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"on-the-challenges-of-detecting-mci-using-eeg","repo_url":"https://github.com/aamixsh/eeg_mci","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"domain-generalization","task_name":"Domain Generalization"},{"task_slug":"eeg-1","task_name":"EEG"},{"task_slug":"eeg","task_name":"Electroencephalogram (EEG)"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"aamixsh/eeg_mci","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"51c03e943a45751a8069e4e7d3792f4af1eab2f67f074e8cc28cf257b95703ad","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}