{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/mesh-convolutional-neural-networks-for-wall","title":"Mesh convolutional neural networks for wall shear stress estimation in 3D artery models","arxiv_id":"2109.04797","date":"2021-09-10","proceeding":null,"authors":["Julian Suk","Pim de Haan","Phillip Lippe","Christoph Brune","Jelmer M. Wolterink"],"abstract":"Computational fluid dynamics (CFD) is a valuable tool for personalised, non-invasive evaluation of hemodynamics in arteries, but its complexity and time-consuming nature prohibit large-scale use in practice. Recently, the use of deep learning for rapid estimation of CFD parameters like wall shear stress (WSS) on surface meshes has been investigated. However, existing approaches typically depend on a hand-crafted re-parametrisation of the surface mesh to match convolutional neural network architectures. In this work, we propose to instead use mesh convolutional neural networks that directly operate on the same finite-element surface mesh as used in CFD. We train and evaluate our method on two datasets of synthetic coronary artery models with and without bifurcation, using a ground truth obtained from CFD simulation. We show that our flexible deep learning model can accurately predict 3D WSS vectors on this surface mesh. Our method processes new meshes in less than 5 [s], consistently achieves a normalised mean absolute error of $\\leq$ 1.6 [%], and peaks at 90.5 [%] median approximation accuracy over the held-out test set, comparing favourably to previously published work. This demonstrates the feasibility of CFD surrogate modelling using mesh convolutional neural networks for hemodynamic parameter estimation in artery models.","url_abs":"https://arxiv.org/abs/2109.04797v3","url_pdf":"https://arxiv.org/pdf/2109.04797v3.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"mesh-convolutional-neural-networks-for-wall","repo_url":"https://github.com/sukjulian/coronary-mesh-convolution","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":{"status":"ok","spdx":"MIT"}}],"tasks":[{"task_slug":"parameter-estimation","task_name":"parameter estimation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2109.04797","atlas_url":"https://app.syntology.ai/?focus=2109.04797","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2109.04797"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2109.04797\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2109.04797"},"call":"get_concepts_for_paper(arxiv_id=\"2109.04797\")"}],"by_repo":[{"repo":"sukjulian/coronary-mesh-convolution","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0,"harvested_for_other_papers":1,"harvested_for":["2212.05023"],"harvested_for_calls":[{"arxiv_id":"2212.05023","tool":"get_harvested_code_for_paper","arguments":{"arxiv_id":"2212.05023"},"call":"get_harvested_code_for_paper(arxiv_id=\"2212.05023\")"}]}],"by_repo_harvested_for_is":"harvested_for: the arXiv ids (as Syntology's graph holds them) of every paper whose samples Syntology's graph links to this repository, in arXiv-id order, complete; the page names the first 3 and says how many more. A link only: it does not say the papers are the same work, that one copied the other, or that the code implements this paper's method; harvested_for_calls gives the get_harvested_code_for_paper call for each arXiv-shaped id among them","by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"9df48fb67f1c51e124294260090e23957fcc0defd13ad016e4ba3bc44f72b887","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}