{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/medical-image-segmentation-with-intent","title":"Medical Image Segmentation with InTEnt: Integrated Entropy Weighting for Single Image Test-Time Adaptation","arxiv_id":"2402.09604","date":"2024-02-14","proceeding":null,"authors":["Haoyu Dong","Nicholas Konz","Hanxue Gu","Maciej A. Mazurowski"],"abstract":"Test-time adaptation (TTA) refers to adapting a trained model to a new domain during testing. Existing TTA techniques rely on having multiple test images from the same domain, yet this may be impractical in real-world applications such as medical imaging, where data acquisition is expensive and imaging conditions vary frequently. Here, we approach such a task, of adapting a medical image segmentation model with only a single unlabeled test image. Most TTA approaches, which directly minimize the entropy of predictions, fail to improve performance significantly in this setting, in which we also observe the choice of batch normalization (BN) layer statistics to be a highly important yet unstable factor due to only having a single test domain example. To overcome this, we propose to instead integrate over predictions made with various estimates of target domain statistics between the training and test statistics, weighted based on their entropy statistics. Our method, validated on 24 source/target domain splits across 3 medical image datasets surpasses the leading method by 2.9% Dice coefficient on average.","url_abs":"https://arxiv.org/abs/2402.09604v2","url_pdf":"https://arxiv.org/pdf/2402.09604v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"medical-image-segmentation-with-intent","repo_url":"https://github.com/mazurowski-lab/single-image-test-time-adaptation","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"image-segmentation","task_name":"Image Segmentation"},{"task_slug":"medical-image-segmentation","task_name":"Medical Image Segmentation"},{"task_slug":"semantic-segmentation","task_name":"Semantic Segmentation"},{"task_slug":"test-time-adaptation","task_name":"Test-time Adaptation"}],"methods":[{"method_slug":"batch-normalization","method_name":"Batch Normalization"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2402.09604","atlas_url":"https://app.syntology.ai/?focus=2402.09604","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2402.09604"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2402.09604\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2402.09604"},"call":"get_concepts_for_paper(arxiv_id=\"2402.09604\")"}],"by_repo":[{"repo":"mazurowski-lab/single-image-test-time-adaptation","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"858f4b54f1540afae55552625d2beba004f37071e035fdb4133531d6064b46d8","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}