{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/matching-the-clinical-reality-accurate-oct","title":"Matching the Clinical Reality: Accurate OCT-Based Diagnosis From Few Labels","arxiv_id":"2010.12316","date":"2020-10-23","proceeding":null,"authors":["Valentyn Melnychuk","Evgeniy Faerman","Ilja Manakov","Thomas Seidl"],"abstract":"Unlabeled data is often abundant in the clinic, making machine learning methods based on semi-supervised learning a good match for this setting. Despite this, they are currently receiving relatively little attention in medical image analysis literature. Instead, most practitioners and researchers focus on supervised or transfer learning approaches. The recently proposed MixMatch and FixMatch algorithms have demonstrated promising results in extracting useful representations while requiring very few labels. Motivated by these recent successes, we apply MixMatch and FixMatch in an ophthalmological diagnostic setting and investigate how they fare against standard transfer learning. We find that both algorithms outperform the transfer learning baseline on all fractions of labelled data. Furthermore, our experiments show that exponential moving average (EMA) of model parameters, which is a component of both algorithms, is not needed for our classification problem, as disabling it leaves the outcome unchanged. Our code is available online: https://github.com/Valentyn1997/oct-diagn-semi-supervised","url_abs":"https://arxiv.org/abs/2010.12316v1","url_pdf":"https://arxiv.org/pdf/2010.12316v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"matching-the-clinical-reality-accurate-oct","repo_url":"https://github.com/Valentyn1997/oct-diagn-semi-supervised","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"diagnostic","task_name":"Diagnostic"},{"task_slug":"medical-image-analysis","task_name":"Medical Image Analysis"},{"task_slug":"retinal-oct-disease-classification","task_name":"Retinal OCT Disease Classification"},{"task_slug":"semi-supervised-image-classification","task_name":"Semi-Supervised Image Classification"},{"task_slug":"transfer-learning","task_name":"Transfer Learning"}],"methods":[{"method_slug":"fixmatch","method_name":"FixMatch"}],"datasets_introduced":[],"methods_introduced":[],"results":[{"leaderboard":"/sota/retinal-oct-disease-classification-on-oct2017","task":"Retinal OCT Disease Classification","dataset":"OCT2017","model":"WideResNet-50-2 (EMA-decay=0.999)","rank_in_archive_order":4,"of":16,"metrics":{"Acc":"99.69"},"uses_additional_data":false}],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"Valentyn1997/oct-diagn-semi-supervised","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"4f3bfcf1652978206ca854280d8ea009fed206d834c24c4d13468c77fcd614cd","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}