{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/mask-of-truth-model-sensitivity-to-unexpected","title":"Mask of truth: model sensitivity to unexpected regions of medical images","arxiv_id":"2412.04030","date":"2024-12-05","proceeding":null,"authors":["Théo Sourget","Michelle Hestbek-Møller","Amelia Jiménez-Sánchez","Jack Junchi Xu","Veronika Cheplygina"],"abstract":"The development of larger models for medical image analysis has led to increased performance. However, it also affected our ability to explain and validate model decisions. Models can use non-relevant parts of images, also called spurious correlations or shortcuts, to obtain high performance on benchmark datasets but fail in real-world scenarios. In this work, we challenge the capacity of convolutional neural networks (CNN) to classify chest X-rays and eye fundus images while masking out clinically relevant parts of the image. We show that all models trained on the PadChest dataset, irrespective of the masking strategy, are able to obtain an Area Under the Curve (AUC) above random. Moreover, the models trained on full images obtain good performance on images without the region of interest (ROI), even superior to the one obtained on images only containing the ROI. We also reveal a possible spurious correlation in the Chaksu dataset while the performances are more aligned with the expectation of an unbiased model. We go beyond the performance analysis with the usage of the explainability method SHAP and the analysis of embeddings. We asked a radiology resident to interpret chest X-rays under different masking to complement our findings with clinical knowledge. Our code is available at https://github.com/TheoSourget/MMC_Masking and https://github.com/TheoSourget/MMC_Masking_EyeFundus","url_abs":"https://arxiv.org/abs/2412.04030v2","url_pdf":"https://arxiv.org/pdf/2412.04030v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"mask-of-truth-model-sensitivity-to-unexpected","repo_url":"https://github.com/theosourget/mmc_masking","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":null},{"paper_slug":"mask-of-truth-model-sensitivity-to-unexpected","repo_url":"https://github.com/theosourget/mmc_masking_eyefundus","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"clinical-knowledge","task_name":"Clinical Knowledge"},{"task_slug":"medical-image-analysis","task_name":"Medical Image Analysis"},{"task_slug":"sensitivity","task_name":"Sensitivity"}],"methods":[{"method_slug":"shap","method_name":"SHAP"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"theosourget/mmc_masking","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"theosourget/mmc_masking_eyefundus","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"b284e90b344343de70df6ba5b573dcbc12b2db44d37eaa32e6853900ed2c1027","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}