{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/machine-learning-for-mechanical-ventilation","title":"Machine Learning for Mechanical Ventilation Control","arxiv_id":"2102.06779","date":"2021-02-12","proceeding":null,"authors":["Daniel Suo","Naman Agarwal","Wenhan Xia","Xinyi Chen","Udaya Ghai","Alexander Yu","Paula Gradu","Karan Singh","Cyril Zhang","Edgar Minasyan","Julienne LaChance","Tom Zajdel","Manuel Schottdorf","Daniel Cohen","Elad Hazan"],"abstract":"We consider the problem of controlling an invasive mechanical ventilator for pressure-controlled ventilation: a controller must let air in and out of a sedated patient's lungs according to a trajectory of airway pressures specified by a clinician. Hand-tuned PID controllers and similar variants have comprised the industry standard for decades, yet can behave poorly by over- or under-shooting their target or oscillating rapidly. We consider a data-driven machine learning approach: First, we train a simulator based on data we collect from an artificial lung. Then, we train deep neural network controllers on these simulators.We show that our controllers are able to track target pressure waveforms significantly better than PID controllers. We further show that a learned controller generalizes across lungs with varying characteristics much more readily than PID controllers do.","url_abs":"https://arxiv.org/abs/2102.06779v4","url_pdf":"https://arxiv.org/pdf/2102.06779v4.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"machine-learning-for-mechanical-ventilation","repo_url":"https://github.com/bobbercheng/ventilator-pressure-prediction","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"tf","reach":{"status":"unanswered"}},{"paper_slug":"machine-learning-for-mechanical-ventilation","repo_url":"https://github.com/abdelghanibelgaid/nnvpp","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"none","reach":{"status":"unanswered"}}],"tasks":[{"task_slug":"machine-learning","task_name":"BIG-bench Machine Learning"}],"methods":[],"datasets_introduced":[{"slug":"google-brain-ventilator-pressure-prediction","name":"Google Brain - Ventilator Pressure Prediction","full_name":""}],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2102.06779","atlas_url":"https://app.syntology.ai/?focus=2102.06779","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2102.06779"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2102.06779\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2102.06779"},"call":"get_concepts_for_paper(arxiv_id=\"2102.06779\")"}],"by_repo":[{"repo":"bobbercheng/ventilator-pressure-prediction","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0},{"repo":"abdelghanibelgaid/nnvpp","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"174ce8c77d2e896fe7b217f9624c81e0c4302eae00625f0f0fe3afc7cd23069f","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}