{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/learning-self-calibrated-optic-disc-and-cup","title":"Learning self-calibrated optic disc and cup segmentation from multi-rater annotations","arxiv_id":"2206.05092","date":"2022-06-10","proceeding":null,"authors":["Junde Wu","Huihui Fang","Fangxin Shang","Zhaowei Wang","Dalu Yang","Wenshuo Zhou","Yehui Yang","Yanwu Xu"],"abstract":"The segmentation of optic disc(OD) and optic cup(OC) from fundus images is an important fundamental task for glaucoma diagnosis. In the clinical practice, it is often necessary to collect opinions from multiple experts to obtain the final OD/OC annotation. This clinical routine helps to mitigate the individual bias. But when data is multiply annotated, standard deep learning models will be inapplicable. In this paper, we propose a novel neural network framework to learn OD/OC segmentation from multi-rater annotations. The segmentation results are self-calibrated through the iterative optimization of multi-rater expertness estimation and calibrated OD/OC segmentation. In this way, the proposed method can realize a mutual improvement of both tasks and finally obtain a refined segmentation result. Specifically, we propose Diverging Model(DivM) and Converging Model(ConM) to process the two tasks respectively. ConM segments the raw image based on the multi-rater expertness map provided by DivM. DivM generates multi-rater expertness map from the segmentation mask provided by ConM. The experiment results show that by recurrently running ConM and DivM, the results can be self-calibrated so as to outperform a range of state-of-the-art(SOTA) multi-rater segmentation methods.","url_abs":"https://arxiv.org/abs/2206.05092v2","url_pdf":"https://arxiv.org/pdf/2206.05092v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"learning-self-calibrated-optic-disc-and-cup","repo_url":"https://github.com/WuJunde/MrPrism","is_official":1,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"segmentation","task_name":"Segmentation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2206.05092","atlas_url":"https://app.syntology.ai/?focus=2206.05092","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2206.05092"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2206.05092\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2206.05092"},"call":"get_concepts_for_paper(arxiv_id=\"2206.05092\")"}],"by_repo":[{"repo":"WuJunde/MrPrism","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"a7321ef631ea9beefd930ed9ed4b864a49d4beb4ffaa055fbbb695373ea2e284","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}