Papers › Joint super-resolution and synthesis of 1 mm isotropic MP-RAGE volumes from clinical...

Joint super-resolution and synthesis of 1 mm isotropic MP-RAGE volumes from clinical MRI exams with scans of different orientation, resolution and contrast

24 Dec 2020arXiv:2012.13340archive 2025-07-28

Juan Eugenio Iglesias, Benjamin Billot, Yael Balbastre, Azadeh Tabari, John Conklin, Daniel C. Alexander, Polina Golland, Brian L. Edlow, Bruce Fischl

Most existing algorithms for automatic 3D morphometry of human brain MRI scans are designed for data with near-isotropic voxels at approximately 1 mm resolution, and frequently have contrast constraints as well - typically requiring T1 scans (e.g., MP-RAGE). This limitation prevents the analysis of millions of MRI scans acquired with large inter-slice spacing ("thick slice") in clinical settings every year. The inability to quantitatively analyze these scans hinders the adoption of quantitative neuroimaging in healthcare, and precludes research studies that could attain huge sample sizes and hence greatly improve our understanding of the human brain. Recent advances in CNNs are producing outstanding results in super-resolution and contrast synthesis of MRI. However, these approaches are very sensitive to the contrast, resolution and orientation of the input images, and thus do not generalize to diverse clinical acquisition protocols - even within sites. Here we present SynthSR, a method to train a CNN that receives one or more thick-slice scans with different contrast, resolution and orientation, and produces an isotropic scan of canonical contrast (typically a 1 mm MP-RAGE). The presented method does not require any preprocessing, e.g., skull stripping or bias field correction. Crucially, SynthSR trains on synthetic input images generated from 3D segmentations, and can thus be used to train CNNs for any combination of contrasts, resolutions and orientations without high-resolution training data. We test the images generated with SynthSR in an array of common downstream analyses, and show that they can be reliably used for subcortical segmentation and volumetry, image registration (e.g., for tensor-based morphometry), and, if some image quality requirements are met, even cortical thickness morphometry. The source code is publicly available at github.com/BBillot/SynthSR.

PaperPDFCode

In Syntology View this paper on Syntology, its page in Syntology's graph. That page lists the repositories linked to the paper, the abstract and the calls for agents.

Open this paper in Syntology's Atlas, the map of the papers in Syntology's graph and their citations.

For agents, on Syntology's MCP service (how to connect):

Code

BBillot/SynthSR officialmentioned in papertfApache-2.0Syntology: no sample linked to this paper (harvested for another paper). Syntology's graph links these samples to SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retraining (arXiv:2107.09559; that paper's own run record: 3 ran (of which 0 constructed an object rather than computing a result; 3 with no instrument failure: 0 honoured, 0 violated, 3 with no contract checked; 0 where Syntology's instrument failed) · 3 unverified); nothing checks that they implement this paper's method. report

Repository list and official/mentioned flags are the archive's, frozen 2025-07-28. Reachability, where shown, is from one Syntology probe window (2026-09-16 to 2026-09-18); repositories not probed show nothing. GitHub stars are not tracked.

A paper named beside a repository with no sample linked to this paper is shown with that paper's own run record, not this paper's: “ran” means executed on a synthesized input, not that the code is correct, and “where Syntology's instrument failed” counts failures of Syntology's instrument, not of the code. Papers are listed in arXiv-id order, at most three per repository.

Code Syntology ran Syntology

Not run by Syntology. Nothing on this page verifies that the listed code works.

Tasks

Image RegistrationSkull StrippingSuper-Resolution

Results from the paper archive 2025-07-28

No leaderboard rows for this paper in the archive.

Report a problem or propose a change · a person checks every report against the paper or source before anything changes; decisions are listed on /corrections