{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/improving-deep-learning-in-arrhythmia","title":"Improving deep learning in arrhythmia Detection: The application of modular quality and quantity controllers in data augmentation","arxiv_id":null,"date":"2024-05-10","proceeding":"Biomedical Signal Processing and Control 2024 5","authors":["Mohammad Usef Khosravi Khaliran","Iman Zabbah","Mehrbod Faraji","Reza Ebrahimpour"],"abstract":"Among the most prevalent diseases with significant fatality rates are cardiac disorders. In recent years, the application of deep learning in diagnosing various cardiac conditions, namely arrhythmia, has gained widespread attention. Nevertheless, deep neural networks struggle to detect arrhythmia due to skewed datasets and a lack of data in different classes. If used effectively, data augmentation can address this gap by adding further synthetic samples in the correct distribution of the corresponding skewed classes. To achieve this, we have instituted the Modular Distribution and Volume Controller method, abbreviated as MDVC. Our method concentrates on both qualitative and quantitative aspects of data augmentation to elevate efficiency and create a significant and varied amount of synthetic samples. Seven distinct methods of data augmentation are utilized in fusion to synthesize samples. Subsequently, the distribution controller determines the most advantageous distribution of artificial samples for each data augmentation technique, emphasizing the dispersion and collision of different classes. The maximum overall data augmentation volume, the volume of each class, and the volume of each data augmentation technique are defined by the volume controller through the novel x, α, and β parameters. Classifying the 17 classes of the MIT-BIH dataset using the MDVC yielded an accuracy of 98.9 % using a 10-fold cross-validation strategy; thus, we have outperformed state-of-the-art data augmentation techniques such as RandAugment and α-trim by 1.3 % and 0.8 %, respectively.","url_abs":"https://www.sciencedirect.com/science/article/abs/pii/S1746809423013733","url_pdf":"https://www.sciencedirect.com/getaccess/pii/S1746809423013733/purchase","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"improving-deep-learning-in-arrhythmia","repo_url":"https://github.com/usefkhosravi/Augment","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":0,"framework":"tf","reach":null}],"tasks":[{"task_slug":"arrhythmia-detection","task_name":"Arrhythmia Detection"},{"task_slug":"data-augmentation","task_name":"Data Augmentation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[{"repo":"usefkhosravi/Augment","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"f4791538e1afa24d987133bc3a74b1a940544a3605f68ec3630727ac8dfce19f","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}