{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/high-dimensional-fast-convolutional-framework","title":"High-dimensional Fast Convolutional Framework (HICU) for Calibrationless MRI","arxiv_id":"2004.08962","date":"2020-04-19","proceeding":null,"authors":["Shen Zhao","Lee C. Potter","Rizwan Ahmad"],"abstract":"Purpose: To present a computational procedure for accelerated, calibrationless magnetic resonance image (Cl-MRI) reconstruction that is fast, memory efficient, and scales to high-dimensional imaging. Theory and Methods: Cl-MRI methods can enable high acceleration rates and flexible sampling patterns, but their clinical application is limited by computational complexity and large memory footprint. The proposed computational procedure, HIgh-dimensional fast ConvolU-tional framework (HICU), provides fast, memory-efficient recovery of unsampled k-space points. For demonstration, HICU is applied to six 2D T2-weighted brain, seven 2D cardiac cine, five 3D knee, and one multi-shot diffusion weighted imaging (MSDWI) datasets. Results: The 2D imaging results show that HICU can offer one to two orders of magnitude computation speedup compared to other Cl-MRI methods without sacrificing imaging quality. The 2D cine and 3D imaging results show that the computational acceleration techniques included in HICU yield computing time on par with SENSE-based compressed sensing methods with up to 3 dB improvement in signal-to-error ratio and better perceptual quality. The MSDWI results demonstrate the feasibility of HICU for a challenging multi-shot echo-planar imaging application. Conclusions: The presented method, HICU, offers efficient computation and scalability as well as extendibility to a wide variety of MRI applications.","url_abs":"https://arxiv.org/abs/2004.08962v3","url_pdf":"https://arxiv.org/pdf/2004.08962v3.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"high-dimensional-fast-convolutional-framework","repo_url":"https://github.com/OSU-CMR/HICU","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"none","reach":null}],"tasks":[{"task_slug":"mri-reconstruction","task_name":"MRI Reconstruction"},{"task_slug":"high","task_name":"Vocal Bursts Intensity Prediction"},{"task_slug":"compressed-sensing","task_name":"compressed sensing"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"OSU-CMR/HICU","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"3ae2d21cc81e46222c07abfcce6674cc93f0d8cab88400c09b027f136f37b14d","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}