{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/fully-convolutional-slice-to-volume","title":"Fully Convolutional Slice-to-Volume Reconstruction for Single-Stack MRI","arxiv_id":"2312.03102","date":"2023-12-05","proceeding":"CVPR 2024 1","authors":["Sean I. Young","Yaël Balbastre","Bruce Fischl","Polina Golland","Juan Eugenio Iglesias"],"abstract":"In magnetic resonance imaging (MRI), slice-to-volume reconstruction (SVR) refers to computational reconstruction of an unknown 3D magnetic resonance volume from stacks of 2D slices corrupted by motion. While promising, current SVR methods require multiple slice stacks for accurate 3D reconstruction, leading to long scans and limiting their use in time-sensitive applications such as fetal fMRI. Here, we propose a SVR method that overcomes the shortcomings of previous work and produces state-of-the-art reconstructions in the presence of extreme inter-slice motion. Inspired by the recent success of single-view depth estimation methods, we formulate SVR as a single-stack motion estimation task and train a fully convolutional network to predict a motion stack for a given slice stack, producing a 3D reconstruction as a byproduct of the predicted motion. Extensive experiments on the SVR of adult and fetal brains demonstrate that our fully convolutional method is twice as accurate as previous SVR methods. Our code is available at github.com/seannz/svr.","url_abs":"https://arxiv.org/abs/2312.03102v2","url_pdf":"https://arxiv.org/pdf/2312.03102v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"fully-convolutional-slice-to-volume","repo_url":"https://github.com/seannz/svr","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":{"status":"ok","spdx":"MIT"}}],"tasks":[{"task_slug":"3d-reconstruction","task_name":"3D Reconstruction"},{"task_slug":"depth-estimation","task_name":"Depth Estimation"},{"task_slug":"motion-estimation","task_name":"Motion Estimation"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"seannz/svr","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0,"harvested_for_other_papers":1,"harvested_for":["Young_Fully_Convolutional_Slice-to-Volume_Reconstruction_for_Single-Stack_MRI_CVPR_2024_paper"],"harvested_for_calls":[]}],"by_repo_harvested_for_is":"harvested_for: the arXiv ids (as Syntology's graph holds them) of every paper whose samples Syntology's graph links to this repository, in arXiv-id order, complete; the page names the first 3 and says how many more. A link only: it does not say the papers are the same work, that one copied the other, or that the code implements this paper's method; harvested_for_calls gives the get_harvested_code_for_paper call for each arXiv-shaped id among them","by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"0c97b067c7782111f4276b78ae2461c400bbd355836bc606bd6698e038525652","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}