{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/fast-mri-reconstruction-how-powerful","title":"Fast MRI Reconstruction: How Powerful Transformers Are?","arxiv_id":"2201.09400","date":"2022-01-23","proceeding":null,"authors":["Jiahao Huang","Yinzhe Wu","Huanjun Wu","Guang Yang"],"abstract":"Magnetic resonance imaging (MRI) is a widely used non-radiative and non-invasive method for clinical interrogation of organ structures and metabolism, with an inherently long scanning time. Methods by k-space undersampling and deep learning based reconstruction have been popularised to accelerate the scanning process. This work focuses on investigating how powerful transformers are for fast MRI by exploiting and comparing different novel network architectures. In particular, a generative adversarial network (GAN) based Swin transformer (ST-GAN) was introduced for the fast MRI reconstruction. To further preserve the edge and texture information, edge enhanced GAN based Swin transformer (EES-GAN) and texture enhanced GAN based Swin transformer (TES-GAN) were also developed, where a dual-discriminator GAN structure was applied. We compared our proposed GAN based transformers, standalone Swin transformer and other convolutional neural networks based GAN model in terms of the evaluation metrics PSNR, SSIM and FID. We showed that transformers work well for the MRI reconstruction from different undersampling conditions. The utilisation of GAN's adversarial structure improves the quality of images reconstructed when undersampled for 30% or higher. The code is publicly available at https://github.com/ayanglab/SwinGANMR.","url_abs":"https://arxiv.org/abs/2201.09400v2","url_pdf":"https://arxiv.org/pdf/2201.09400v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"fast-mri-reconstruction-how-powerful","repo_url":"https://github.com/ayanglab/swinganmr","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":null,"task_name":"Generative Adversarial Network"},{"task_slug":"mri-reconstruction","task_name":"MRI Reconstruction"}],"methods":[{"method_slug":"attention","method_name":"Attention"},{"method_slug":"dense-connections","method_name":"Dense Connections"},{"method_slug":"layer-normalization","method_name":"Layer Normalization"},{"method_slug":"linear-layer","method_name":"Linear Layer"},{"method_slug":"multi-head-attention","method_name":"Multi-Head Attention"},{"method_slug":"residual-connection","method_name":"Residual Connection"},{"method_slug":"softmax","method_name":"Softmax"},{"method_slug":"stochastic-depth","method_name":"Stochastic Depth"},{"method_slug":"swin-transformer","method_name":"Swin Transformer"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"ayanglab/swinganmr","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0,"harvested_for_other_papers":1,"harvested_for":["2103.14030"],"harvested_for_calls":[{"arxiv_id":"2103.14030","tool":"get_harvested_code_for_paper","arguments":{"arxiv_id":"2103.14030"},"call":"get_harvested_code_for_paper(arxiv_id=\"2103.14030\")"}]}],"by_repo_harvested_for_is":"harvested_for: the arXiv ids (as Syntology's graph holds them) of every paper whose samples Syntology's graph links to this repository, in arXiv-id order, complete; the page names the first 3 and says how many more. A link only: it does not say the papers are the same work, that one copied the other, or that the code implements this paper's method; harvested_for_calls gives the get_harvested_code_for_paper call for each arXiv-shaped id among them","by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"879cb248b925eef7d450f34b022cb85321a72561e29ec54ac0596cc5632ade61","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}