{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/evaluation-framework-for-algorithms","title":"Evaluation framework for algorithms segmenting short axis cardiac MRI.","arxiv_id":null,"date":"2009-07-09","proceeding":"The MIDAS Journal 2009 7","authors":["Radau Perry","Lu Yingli","Connelly Kim","Paul Gideon","Dick Alexander J","Wright Graham A"],"abstract":"The motivation of the segmentation challenge is to quantitatively analyze global and regional cardiac function from cine magnetic resonance (MR) images, clinical parameters such as ejection fraction (EF), left ventricle myocardium mass (MM), and stroke volume (SV) are required. Calculations of these parameters depend upon accurate delineation of endocardial and epicardial contours of the left ventricle (LV). Manual delineation is time-consuming and tedious and has high inter-observer variability. Thus, fully automatic LV segmentation is desirable. The automatic segmentation of the LV in cine MR typically faces four challenges: 1) the overlap between the intensity distributions within the cardiac regions; 2) the lack of edge information; 3) the shape variability of the endocardial and epicardial contours across slices and phases; and 4) the inter-subject variability of these factors. A number of methods have been proposed for (semi-) automatic LV segmentation, including using a probability atlas [1], dynamic programming [2-3], fuzzy clustering [4], a deformable model [5], an active appearance model [6], a variational and level set [7-10], graph cuts [11-12] and an image-driven approach [13]. For a complete review of recent literature describing cardiac segmentation techniques, see [14]. Although the segmentation results have improved, accurate LV segmentation is still acknowledged as a difficult problem. The goals of this contest are to compare LV segmentation methods by providing an evaluation system, and a database of images and expert contours. Comparing segmentation results across research studies can be difficult due to unspecified differences in the method or implementation of evaluation metrics. This contest will provide open-source code for contour evaluation. Furthermore, the database will provide a set of images such that confounding segmentation differences due to image quality or pathology could be eliminated.","url_abs":"https://doi.org/10.54294/g80ruo","url_pdf":"https://doi.org/10.54294/g80ruo","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[],"tasks":[{"task_slug":"cardiac-segmentation","task_name":"Cardiac Segmentation"},{"task_slug":"lv-segmentation","task_name":"LV Segmentation"},{"task_slug":"segmentation","task_name":"Segmentation"}],"methods":[],"datasets_introduced":[{"slug":"sunnybrook-cardiac-data","name":"Sunnybrook Cardiac Data","full_name":"Sunnybrook Cardiac Data"}],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":"the archive holds no code link for this paper","arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"c5559474047274ac43e3b62607724c398510438e9c5c46bda74a9f00d251dbd1","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}