{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/enhancing-synthetic-ct-from-cbct-via-1","title":"Enhancing Synthetic CT from CBCT via Multimodal Fusion and End-To-End Registration","arxiv_id":"2507.06067","date":"2025-07-08","proceeding":null,"authors":["Maximilian Tschuchnig","Lukas Lamminger","Philipp Steininger","Michael Gadermayr"],"abstract":"Cone-Beam Computed Tomography (CBCT) is widely used for intraoperative imaging due to its rapid acquisition and low radiation dose. However, CBCT images typically suffer from artifacts and lower visual quality compared to conventional Computed Tomography (CT). A promising solution is synthetic CT (sCT) generation, where CBCT volumes are translated into the CT domain. In this work, we enhance sCT generation through multimodal learning by jointly leveraging intraoperative CBCT and preoperative CT data. To overcome the inherent misalignment between modalities, we introduce an end-to-end learnable registration module within the sCT pipeline. This model is evaluated on a controlled synthetic dataset, allowing precise manipulation of data quality and alignment parameters. Further, we validate its robustness and generalizability on two real-world clinical datasets. Experimental results demonstrate that integrating registration in multimodal sCT generation improves sCT quality, outperforming baseline multimodal methods in 79 out of 90 evaluation settings. Notably, the improvement is most significant in cases where CBCT quality is low and the preoperative CT is moderately misaligned.","url_abs":"https://arxiv.org/abs/2507.06067v1","url_pdf":"https://arxiv.org/pdf/2507.06067v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"enhancing-synthetic-ct-from-cbct-via-1","repo_url":"https://github.com/maxtschuchnig/enhancingsyntheticctfromcbctviamultimodalfusionandend-to-endregistration","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"computed-tomography-ct","task_name":"Computed Tomography (CT)"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"maxtschuchnig/enhancingsyntheticctfromcbctviamultimodalfusionandend-to-endregistration","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"9fa8eed10edaac3bdd8480f468b79a85cb3a09f1c4e8b93673e2859443a41473","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}