{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/electrocardioguard-preventing-patient","title":"ElectroCardioGuard: Preventing Patient Misidentification in Electrocardiogram Databases through Neural Networks","arxiv_id":"2306.06196","date":"2023-06-09","proceeding":null,"authors":["Michal Seják","Jakub Sido","David Žahour"],"abstract":"Electrocardiograms (ECGs) are commonly used by cardiologists to detect heart-related pathological conditions. Reliable collections of ECGs are crucial for precise diagnosis. However, in clinical practice, the assignment of captured ECG recordings to incorrect patients can occur inadvertently. In collaboration with a clinical and research facility which recognized this challenge and reached out to us, we present a study that addresses this issue. In this work, we propose a small and efficient neural-network based model for determining whether two ECGs originate from the same patient. Our model demonstrates great generalization capabilities and achieves state-of-the-art performance in gallery-probe patient identification on PTB-XL while utilizing 760x fewer parameters. Furthermore, we present a technique leveraging our model for detection of recording-assignment mistakes, showcasing its applicability in a realistic scenario. Finally, we evaluate our model on a newly collected ECG dataset specifically curated for this study, and make it public for the research community.","url_abs":"https://arxiv.org/abs/2306.06196v2","url_pdf":"https://arxiv.org/pdf/2306.06196v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"electrocardioguard-preventing-patient","repo_url":"https://github.com/captaintrojan/electrocardioguard","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"ecg-patient-identification","task_name":"ECG Patient Identification"},{"task_slug":"ecg-patient-identification-gallery-probe","task_name":"ECG Patient Identification (gallery-probe)"},{"task_slug":"efficient-neural-network","task_name":"Efficient Neural Network"}],"methods":[{"method_slug":"cdil-cnn","method_name":"CDIL-CNN"},{"method_slug":"triplet-loss","method_name":"Triplet Loss"}],"datasets_introduced":[],"methods_introduced":[],"results":[{"leaderboard":"/sota/ecg-patient-identification-gallery-probe-on","task":"ECG Patient Identification (gallery-probe)","dataset":"CODE-15%","model":"ElectroCardioGuard","rank_in_archive_order":1,"of":1,"metrics":{"Accuracy":"60.3%"},"uses_additional_data":false},{"leaderboard":"/sota/ecg-patient-identification-gallery-probe-on-2","task":"ECG Patient Identification (gallery-probe)","dataset":"PTB Diagnostic ECG Database","model":"ElectroCardioGuard","rank_in_archive_order":1,"of":1,"metrics":{"Accuracy":"77.0%"},"uses_additional_data":true},{"leaderboard":"/sota/ecg-patient-identification-gallery-probe-on-1","task":"ECG Patient Identification (gallery-probe)","dataset":"PTB-XL","model":"ElectroCardioGuard","rank_in_archive_order":1,"of":1,"metrics":{"Accuracy":"58.3%"},"uses_additional_data":true}],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"captaintrojan/electrocardioguard","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"5b79e17392a84c2d2c7dad965944eccefe746acbb5c3e7c0d2903cd0a4fe9350","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}