{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/detailed-retinal-vessel-segmentation-without","title":"Synthetic optical coherence tomography angiographs for detailed retinal vessel segmentation without human annotations","arxiv_id":"2306.10941","date":"2023-06-19","proceeding":null,"authors":["Linus Kreitner","Johannes C. Paetzold","Nikolaus Rauch","Chen Chen","Ahmed M. Hagag","Alaa E. Fayed","Sobha Sivaprasad","Sebastian Rausch","Julian Weichsel","Bjoern H. Menze","Matthias Harders","Benjamin Knier","Daniel Rueckert","Martin J. Menten"],"abstract":"Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that can acquire high-resolution volumes of the retinal vasculature and aid the diagnosis of ocular, neurological and cardiac diseases. Segmenting the visible blood vessels is a common first step when extracting quantitative biomarkers from these images. Classical segmentation algorithms based on thresholding are strongly affected by image artifacts and limited signal-to-noise ratio. The use of modern, deep learning-based segmentation methods has been inhibited by a lack of large datasets with detailed annotations of the blood vessels. To address this issue, recent work has employed transfer learning, where a segmentation network is trained on synthetic OCTA images and is then applied to real data. However, the previously proposed simulations fail to faithfully model the retinal vasculature and do not provide effective domain adaptation. Because of this, current methods are unable to fully segment the retinal vasculature, in particular the smallest capillaries. In this work, we present a lightweight simulation of the retinal vascular network based on space colonization for faster and more realistic OCTA synthesis. We then introduce three contrast adaptation pipelines to decrease the domain gap between real and artificial images. We demonstrate the superior segmentation performance of our approach in extensive quantitative and qualitative experiments on three public datasets that compare our method to traditional computer vision algorithms and supervised training using human annotations. Finally, we make our entire pipeline publicly available, including the source code, pretrained models, and a large dataset of synthetic OCTA images.","url_abs":"https://arxiv.org/abs/2306.10941v2","url_pdf":"https://arxiv.org/pdf/2306.10941v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"detailed-retinal-vessel-segmentation-without","repo_url":"https://github.com/tum-aimed/octa-seg","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"pytorch","reach":null}],"tasks":[{"task_slug":"domain-adaptation","task_name":"Domain Adaptation"},{"task_slug":"retinal-vessel-segmentation","task_name":"Retinal Vessel Segmentation"},{"task_slug":"segmentation","task_name":"Segmentation"},{"task_slug":"transfer-learning","task_name":"Transfer Learning"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":"https://syntology.ai/paper/2306.10941","atlas_url":"https://app.syntology.ai/?focus=2306.10941","mcp":null,"developers":"https://syntology.ai/developers","held":true,"reason":"arxiv_id_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"agent_calls":[{"tool":"get_citation_path","arguments":{"paper_1":"2306.10941"},"arguments_in":{"paper_2":"another paper's arXiv id or title"},"call":"get_citation_path(paper_1=\"2306.10941\", paper_2=\"…\")"},{"tool":"get_concepts_for_paper","arguments":{"arxiv_id":"2306.10941"},"call":"get_concepts_for_paper(arxiv_id=\"2306.10941\")"}],"by_repo":[{"repo":"tum-aimed/octa-seg","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"b6f1edb2eb6e6eecd57a6edfe93961cbb2abd565aa4f860700c9cecca567b64f","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}