{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/dataset-of-standard-tests-of-nafion-112","title":"Dataset of Standard Tests of Nafion 112 Membrane and Membrane Electrode Assembly (MEA) Activation Tests of Proton Exchange Membrane (PEM) Fuel Cell","arxiv_id":null,"date":"2020-02-27","proceeding":"ChemRxiv 2020 2","authors":["Sarmin Hamidi","Sepand Haghighi","Kasra Askari"],"abstract":"Reported data in this paper are about Nafion 112 membrane standard tests and MEA activation tests of PEM fuel cell in various operation condition. Dataset include two general electrochemical analysis method, Polarization and Impedance curves. In this dataset, effect of different pressure of H2/O2 gas, different voltages and various humidity conditions in several steps are considered. Details of experimental methods has been explained in this paper. Behavior of PEM fuel cell during distinct operation condition tests, activation procedure and different operation condition before and after activation analysis can be concluded from data. In Polarization curves, voltage and power density change as a function of flows of H2/O2 and relative humidity. Resistance of the used equivalent circuit of fuel cell can be calculated from Impedance data. Thus, experimental response of the cell is obvious in the presented data, which is useful in depth analysis, simulation and material performance investigation in PEM fuel cell researches.","url_abs":"https://chemrxiv.org/engage/chemrxiv/article-details/60c748624c8919b500ad2ef3","url_pdf":"https://chemrxiv.org/engage/api-gateway/chemrxiv/assets/orp/resource/item/60c748624c8919b500ad2ef3/original/dataset-of-standard-tests-of-nafion-112-membrane-and-membrane-electrode-assembly-mea-activation-tests-of-proton-exchange-membrane-pem-fuel-cell.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"dataset-of-standard-tests-of-nafion-112","repo_url":"https://github.com/ECSIM/pem-dataset1","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"none","reach":null}],"tasks":[],"methods":[],"datasets_introduced":[{"slug":"pem-fuel-cell-dataset","name":"PEM Fuel Cell Dataset","full_name":"Proton Exchange Membrane (PEM) Fuel Cell Dataset"}],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[{"repo":"ECSIM/pem-dataset1","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"5eab70da853ecafb1738ec9a9c476eb53bf5c3777407fe46fe9b7c20a7eb7dea","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}