{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/classification-of-mitral-regurgitation-from","title":"Classification of Mitral Regurgitation from Cardiac Cine MRI using Clinically-Interpretable Morphological Features","arxiv_id":"2408.11532","date":"2024-08-21","proceeding":null,"authors":["Y. On","K. Vimalesvaran","S. Zaman","M. Shun-Shin","J. Howard","N. Linton","G. Cole","A. A. Bharath","M. Varela"],"abstract":"The assessment of mitral regurgitation (MR) using cardiac MRI, particularly Cine MRI, is a promising technique due to its wide availability. However, some of the temporal information available in clinical Cine MRI may not be fully utilised, as it requires detailed temporal analysis across different cardiac views. We propose a new approach to identify MR which automatically extracts 4-dimensional (3D + Time) morphological features from the reconstructed mitral annulus (MA) using Cine long-axis (LAX) views MRI. Our feature extraction involves locating the MA insertion points to derive the reconstructed MA geometry and displacements, resulting in a total of 187 candidate features. We identify the 25 most relevant mitral valve features using minimum-redundancy maximum-relevance (MRMR) feature selection technique. We then apply linear discriminant analysis (LDA) and random forest (RF) model to determine the presence of MR. Both LDA and RF demonstrate good performance, with accuracies of 0.72+/-0.05 and 0.73+/-0.09, respectively, in a 5-fold cross-validation analysis. This approach will be incorporated in an automatic tool to identify valvular diseases from Cine MRI by integrating both handcrafted and deep features. Our tool will facilitate the diagnosis of valvular disease from conventional cardiac MRI scans with no additional scanning or image analysis penalty. All code is made available on an open-source basis at: https://github.com/HenryOn2021/MA_Morphological_Features.","url_abs":"https://arxiv.org/abs/2408.11532v2","url_pdf":"https://arxiv.org/pdf/2408.11532v2.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"classification-of-mitral-regurgitation-from","repo_url":"https://github.com/HenryOn2021/MA_Morphological_Features","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":1,"framework":"none","reach":null}],"tasks":[{"task_slug":"feature-selection","task_name":"feature selection"}],"methods":[{"method_slug":"feature-selection","method_name":"Feature Selection"},{"method_slug":"lda","method_name":"LDA"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"HenryOn2021/MA_Morphological_Features","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"f1d64d9bbf11062fcc0e7061f31ffd219462a54d33f25f7dc180a5dd188ce616","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}