{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/cardiologist-level-arrhythmia-detection-and","title":"Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network","arxiv_id":null,"date":"2019-01-07","proceeding":"Nature Medicine 2019 1","authors":["Awni Y. Hannun","Pranav Rajpurkar","Masoumeh Haghpanahi","Geoffrey H. Tison","Codie Bourn","Mintu P. Turakhia","Andrew Y. Ng"],"abstract":"Computerized electrocardiogram (ECG) interpretation plays a critical role in the clinical ECG workflow. Widely available digital ECG data and the algorithmic paradigm of deep learning present an opportunity to substantially improve the accuracy and scalability of automated ECG analysis. However, a comprehensive evaluation of an end-to-end deep learning approach for ECG analysis across a wide variety of diagnostic classes has not been previously reported. Here, we develop a deep neural network (DNN) to classify 12 rhythm classes using 91,232 single-lead ECGs from 53,549 patients who used a single-lead ambulatory ECG monitoring device. When validated against an independent test dataset annotated by a consensus committee of board-certified practicing cardiologists, the DNN achieved an average area under the receiver operating characteristic curve (ROC) of 0.97. The average F1 score, which is the harmonic mean of the positive predictive value and sensitivity, for the DNN (0.837) exceeded that of average cardiologists (0.780). With specificity fixed at the average specificity achieved by cardiologists, the sensitivity of the DNN exceeded the average cardiologist sensitivity for all rhythm classes. These findings demonstrate that an end-to-end deep learning approach can classify a broad range of distinct arrhythmias from single-lead ECGs with high diagnostic performance similar to that of cardiologists. If confirmed in clinical settings, this approach could reduce the rate of misdiagnosed computerized ECG interpretations and improve the efficiency of expert human ECG interpretation by accurately triaging or prioritizing the most urgent conditions.\r\n\r\nDataset available from: https://irhythm.github.io/cardiol_test_set/","url_abs":"https://doi.org/10.1038/s41591-018-0268-3","url_pdf":"https://arxiv.org/pdf/1707.01836.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[],"tasks":[{"task_slug":"arrhythmia-detection","task_name":"Arrhythmia Detection"},{"task_slug":"diagnostic","task_name":"Diagnostic"},{"task_slug":"electrocardiography-ecg","task_name":"Electrocardiography (ECG)"},{"task_slug":"classification","task_name":"General Classification"},{"task_slug":"rhythm","task_name":"Rhythm"},{"task_slug":"sensitivity","task_name":"Sensitivity"},{"task_slug":"specificity","task_name":"Specificity"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[{"leaderboard":"/sota/arrhythmia-detection-on-cardiologist-level-12","task":"Arrhythmia Detection","dataset":"\"Cardiologist-level\" 12-rhythm ECG dataset","model":"DNN","rank_in_archive_order":1,"of":2,"metrics":{"F1 (Sequence)":"0.807","F1 (Set)":"0.837"},"uses_additional_data":false},{"leaderboard":"/sota/arrhythmia-detection-on-cardiologist-level-12","task":"Arrhythmia Detection","dataset":"\"Cardiologist-level\" 12-rhythm ECG dataset","model":"Cardiologists Averaged","rank_in_archive_order":2,"of":2,"metrics":{"F1 (Sequence)":"0.753","F1 (Set)":"0.780"},"uses_additional_data":false}],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":"the archive holds no code link for this paper","arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"8a457af984d056a75cc821279af124ea4f06d15a58f9ad2e0c8a633d07a0da6c","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}