{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/blood-flow-speed-estimation-with-optical","title":"Blood Flow Speed Estimation with Optical Coherence Tomography Angiography Images","arxiv_id":null,"date":"2025-01-01","proceeding":"CVPR 2025 1","authors":["Wensheng Cheng","Zhenghong Li","Jiaxiang Ren","Hyomin Jeong","Congwu Du","Yingtian Pan","Haibin Ling"],"abstract":"    Estimating blood flow speed is essential in many medical and physiological applications, yet it is extremely challenging due to complex vascular structure and flow dynamics, particularly for cerebral cortex regions. Existing techniques, such as Optical Doppler Tomography (ODT), generally require complex hardware control and signal processing, and still suffer from inherent system-level artifacts. To address these challenges, we propose a new learning-based approach named OCTA-Flow, which directly estimates vascular blood flow speed from Optical Coherence Tomography Angiography (OCTA) images that are commonly used for vascular structure analysis. OCTA-Flow employs several novel components to achieve this goal. First, using an encoder-decoder architecture, OCTA-Flow leverages ODT data as pseudo labels during training, thus bypassing the difficulty of collecting ground truth data. Second, to capture the relationship between vessels of varying scales and their flow speed, we design an Adaptive Window Fusion module that employs multiscale window attention. Third, to mitigate ODT artifacts, we incorporate a Conditional Random Field Decoder that promotes smoothness and consistency in the estimated blood flow. Together, these innovations enable OCTA-Flow to effectively produce accurate flow estimation, suppress the artifacts in ODT, and enhance practicality, benefiting from the established techniques of OCTA data acquisition. The code and data are available at https://github.com/Spritea/OCTA-Flow.    ","url_abs":"http://openaccess.thecvf.com//content/CVPR2025/html/Cheng_Blood_Flow_Speed_Estimation_with_Optical_Coherence_Tomography_Angiography_Images_CVPR_2025_paper.html","url_pdf":"http://openaccess.thecvf.com//content/CVPR2025/papers/Cheng_Blood_Flow_Speed_Estimation_with_Optical_Coherence_Tomography_Angiography_Images_CVPR_2025_paper.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"blood-flow-speed-estimation-with-optical","repo_url":"https://github.com/spritea/octa-flow","is_official":1,"mentioned_in_paper":1,"mentioned_in_github":0,"framework":"pytorch","reach":{"status":"ok"}}],"tasks":[{"task_slug":"decoder","task_name":"Decoder"}],"methods":[{"method_slug":"speed","method_name":"SPEED"}],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"no_arxiv_id","checked_against":null,"by_repo":[{"repo":"spritea/octa-flow","kind":"official","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"e5f3a05d3f4242a27018db468efe6302935a3594ad6c22d5fcc978a459ad607d","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}