{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/paper/an-automated-system-for-epilepsy-detection","title":"An Automated System for Epilepsy Detection using EEG Brain Signals based on Deep Learning Approach","arxiv_id":"1801.05412","date":"2018-01-16","proceeding":null,"authors":["Ihsan Ullah","Muhammad Hussain","Emad-ul-Haq Qazi","Hatim AboAlSamh"],"abstract":"Epilepsy is a neurological disorder and for its detection, encephalography\n(EEG) is a commonly used clinical approach. Manual inspection of EEG brain\nsignals is a time-consuming and laborious process, which puts heavy burden on\nneurologists and affects their performance. Several automatic techniques have\nbeen proposed using traditional approaches to assist neurologists in detecting\nbinary epilepsy scenarios e.g. seizure vs. non-seizure or normal vs. ictal.\nThese methods do not perform well when classifying ternary case e.g. ictal vs.\nnormal vs. inter-ictal; the maximum accuracy for this case by the\nstate-of-the-art-methods is 97+-1%. To overcome this problem, we propose a\nsystem based on deep learning, which is an ensemble of pyramidal\none-dimensional convolutional neural network (P-1D-CNN) models. In a CNN model,\nthe bottleneck is the large number of learnable parameters. P-1D-CNN works on\nthe concept of refinement approach and it results in 60% fewer parameters\ncompared to traditional CNN models. Further to overcome the limitations of\nsmall amount of data, we proposed augmentation schemes for learning P-1D-CNN\nmodel. In almost all the cases concerning epilepsy detection, the proposed\nsystem gives an accuracy of 99.1+-0.9% on the University of Bonn dataset.","url_abs":"http://arxiv.org/abs/1801.05412v1","url_pdf":"http://arxiv.org/pdf/1801.05412v1.pdf","source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","row_kind":"abstracts"},"code_links":[{"paper_slug":"an-automated-system-for-epilepsy-detection","repo_url":"https://github.com/majorash/eeg_epilepsy_conv1d","is_official":0,"mentioned_in_paper":0,"mentioned_in_github":1,"framework":"none","reach":null}],"tasks":[{"task_slug":"eeg-1","task_name":"EEG"},{"task_slug":"eeg","task_name":"Electroencephalogram (EEG)"}],"methods":[],"datasets_introduced":[],"methods_introduced":[],"results":[],"syntology":{"syntology_url":null,"atlas_url":null,"mcp":null,"developers":"https://syntology.ai/developers","held":null,"reason":"arxiv_id_not_in_atlas","checked_against":{"atlas_ids":549449,"atlas_ids_sha256":"afd72399dafd9906e9062927f70655952385a3d75488558e1f0484e950ab09b7","read_at":"2026-10-05T01:46:21Z"},"by_repo":[{"repo":"majorash/eeg_epilepsy_conv1d","kind":"listed","samples":0,"ran":0,"instrument":0,"unverified":0}],"by_repo_is":"one row per repository in the archive's code links, Syntology's graph links or the samples; samples 0 means no sample is linked to this paper, a statement about Syntology's coverage, not about the repository: with harvested_for_other_papers present, Syntology harvested the repository for that many other papers, and without it, Syntology harvested nothing from it; placed_by_identical_code counts samples whose link records no repository, placed here because identical code was harvested from this repository for another paper; ran counts executions on a synthesized input and instrument counts failures of Syntology's instrument, not of the code"},"code_links_note":null,"arxiv_metadata":null,"syntology_extracted_results":null,"record_sha256":"aa6efa6f2536cbc062325011e2db7419b790ad0aec571ae94bf88e8dba29fd48","record_changed_at":"2026-09-28","record_changed_at_basis":"first_hashed"}