{"about":{"non_affiliation":"Code with Papers and Syntology are not affiliated with, endorsed by, or sponsored by Papers with Code, Meta, or the pwc-archive mirror.","site":"https://codewithpapers.app","licence":"CC BY-SA 4.0","licence_url":"https://creativecommons.org/licenses/by-sa/4.0/legalcode","attribution":"https://codewithpapers.app/attribution","modified":"archive material modified by Syntology; see the attribution page","syntology":{"site":"https://syntology.ai","developers":"https://syntology.ai/developers","mcp":{"server":"https://syntology.ai/mcp","transport":"streamable-http","server_card":"https://syntology.ai/.well-known/mcp/server-card.json","auth":{"type":"trial token, no account","trial_token":"https://syntology.ai/api/oauth/trial/token","method":"POST","docs":"https://syntology.ai/developers"}},"have":"https://syntology.ai/api/graph/have?x=<method, arXiv id or title> (free, answers coverage only)","paper_base":"https://syntology.ai/paper/","atlas_base":"https://app.syntology.ai/?focus="},"machine_readable":[{"url":"https://codewithpapers.app/llms.txt","what":"the machine catalog: every machine-readable file, counted"},{"url":"https://codewithpapers.app/index/manifest.json","what":"paper-to-code index by arXiv id, with Syntology's counts"},{"url":"https://codewithpapers.app/search/manifest.json","what":"site search index (titles, authors) and its files"},{"url":"https://codewithpapers.app/download","what":"bulk files: Syntology's layer, described there"},{"url":"https://codewithpapers.app/build_manifest.json","what":"the build record: inputs, counts, exclusions, probes"}]},"url":"/dataset/cpsc2019","name":"CPSC2019","full_name":"The 2nd China Physiological Signal Challenge (CPSC 2019)","description_markdown":"# Introduction\r\n\r\nThe China Physiological Signal Challenge 2019 (CPSC 2019) aims to encourage the development of algorithms for challenging QRS detection and heart rate (HR) estimation from short-term single-lead ECG recordings usually with low signal quality and/or abnormal rhythm waveforms.\r\n\r\nECG signal provides an important role in non-invasively monitoring and clinical diagnosis for cardiovascular disease (CVD). Detection of QRS complex is an essential step for ECG signal processing, and can benefit the following HR calculation and abnormal situation analysis. Although detection methods of QRS complex have been severely tracked throughout the last several decades, accurate QRS location and HR estimation are still challenging in noisy signal episode or abnormal rhythm waveforms, especially when the ECG recordings are from the wearable dynamic ECG acquisition. It is true that many of the developed QRS detection algorithms can achieve high accuracy (over 99% in sensitivity and positive predictivity) when tested over the standard ECG databases such as MIT-BIH Arrhythmia Database or AHA Database [1]. However, these algorithms may not be able to perform well when used in the daily life environment that will cause severe noises and significantly reduce the signal quality. A recent study confirmed that none of the common QRS algorithms can obtain 80% detection accuracy when tested in a common dynamic noisy ECG database [2]. Thus, in this challenge, we provide a new ECG database containing noisy ECG episodes and/or signals with different arrhythmia patterns, encouraging participants to develop more efficient and robust algorithms QRS detection and HR estimation. In addition, it is worth to note that, although HR can be calculated from the detection results of QRS complexes, HR can be still estimated without QRS detection step [3,4].\r\n\r\n# Challenge Data\r\nTraining data consists of 2,000 single-lead ECG recordings collected from patients with cardiovascular disease (CVD), each of the recording last for 10 s. Test set contains similar ECG recordings of same lengths, which is unavailable to public and will remain private for the purpose of scoring for the duration of the Challenge and for some period afterwards. ECG recordings were obtained from multiple sources using a variety of instrumentation, although in all cases they are presented as 500 Hz sample rate here. All recordings were provided in MATLAB format (each including two .mat file: one is ECG data and another one is the corresponding QRS annotation file). Pan &Tompkins (P&T) algorithm [5,6] is also provided as benchmark or comparable algorithm.\r\n\r\nAlthough QRS detection and HR estimation are widely studied by lots of researchers for many years, accurate detection is still really challenging in this Challenge due to the QRS amplitude variation, QRS morphological variation, and occurrence of intense variability in the intervals between beats, different arrhythmias, as well as noises.\r\n\r\n# Reference\r\n1. G.B. Moody, R.G. Mark, The impact of the MIT-BIH arrhythmia database, IEEE Engineering in Medicine & Biology Magazine the Quarterly Magazine of the Engineering in Medicine & Biology Society, 20 (2001) 45-50.\r\n2. Liu, F.F.; Wei, S.S.; Li, Y.B.; Jiang, X.E.; Zhang, Z.M.; Liu, C.Y., Performance analysis of ten common qrs detectors on different ecg application cases. Journal of Healthcare Engineering 2018, 2018, ID 9050812.\r\n3. J.J. Gieraltowski, K. Ciuchcinski, I. Grzegorczyk, K. Kosna, Heart rate variability discovery: Algorithm for detection of heart rate from noisy, multimodal recordings, Computing in Cardiology, 2014, pp. 253-256.\r\n4. J. Gieraltowski, K. Ciuchcinski, I. Grzegorczyk, K. Kosna, M. Solinski, P.Podziemski, RS slope detection algorithm for extraction of heart rate from noisy, multimodal recordings, Physiological Measurement, 36 (2015) 1743-1761.\r\n5. P.S. Hamilton, W.J. Tompkins, Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database, Biomedical Engineering, IEEE Transactions on, (1986) 1157-1165.\r\n6. J. Pan, W.J. Tompkins, A real-time QRS detection algorithm, Biomedical Engineering, IEEE Transactions on, (1985) 230-236.\r\n7. ANSI-AAMI (1998). Testing and reporting performance results of cardiac rhythm and st segment measurement algorithms, ANSI-AAMI:EC57.","description_withheld":null,"homepage":"http://2019.icbeb.org/Challenge.html","introduced_date":null,"introduced_date_note":null,"introduced_by":null,"license":null,"modalities":[{"name":"Medical","url":"/datasets/modality/medical"}],"tasks":[{"name":"ECG QRS Detection","url":"/task/ecg-qrs-detection","datasets_with_task":"/datasets/task/ecg-qrs-detection"}],"languages":[{"name":"English","url":"/datasets/language/english"}],"variants":["CPSC2019"],"data_loaders":[{"repo":"https://github.com/DeepPSP/torch_ecg","url":"http://2019.icbeb.org/Challenge.html","frameworks":["pytorch"]}],"num_papers_in_archive":1,"source":{"archive":"pwc-archive (Hugging Face), CC BY-SA 4.0","snapshot":"2025-07-28"},"benchmarks":[],"papers":{"order":"date (newest first), then slug","population":"every paper with a leaderboard row on this dataset's benchmarks (the benchmark-backed subset): the archive's own papers-using-this-dataset list was never published, so this is not that list; num_papers_in_archive is the archive's own count","page":1,"pages_in_order":1,"rows_per_page":100,"shown":0,"of":0,"counts":{"papers_with_a_benchmark_row":0,"with_a_code_link":0,"where_syntology_ran_a_sample":0,"not_listed_spam_title":0,"listed":0,"listed_where_code_ran":0,"where_syntology_ran_a_sample_split":{"with_a_run_with_no_instrument_failure":0,"every_run_a_failure_of_syntologys_instrument":0,"listed_with_a_run_with_no_instrument_failure":0,"listed_every_run_a_failure_of_syntologys_instrument":0,"filter":{"states":["a run with no instrument failure","any run, instrument failures included"],"default":"a run with no instrument failure","note":"on the 'only where code ran' pages the default hides, in the browser, the rows where every run was a failure of Syntology's instrument; the second state shows them again. Rows are hidden, never re-ordered; these twins list every row"}},"definition":"distinct papers with at least one leaderboard row on this dataset's benchmarks; 'where Syntology ran a sample' counts papers with at least one harvested sample that ran, which is not a correctness claim"},"items":[],"full_list":"papers_with_a_benchmark_row: every listed paper, in this order"},"papers_with_a_benchmark_row":[],"papers_where_code_ran":0,"papers_where_code_ran_first_page":null,"papers_where_code_ran_caption":"We ran code from the paper's repository; we did not run it on this dataset or check it against this dataset's benchmarks.","pages":[],"row_route":"each paper's syntology object carries sample_list (this site's paper page, #ran), syntology_url (syntology.ai's page for the paper, only when that route probed live) and mcp (the agent call that lists the paper's harvested samples; not a verdict on the paper)","developers":"https://syntology.ai/developers","syntology_totals":{"read_at":"2026-10-05T00:36:11+00:00","papers_with_samples":0,"samples_harvested":0,"samples_ran":0,"samples_constructed":0,"samples_ran_checked":0,"samples_ran_instrument_failed":0,"samples_unverified":0,"pointer_only_for_licence":0,"papers_with_no_sample_that_ran":0,"papers_with_a_sample_that_ran":0,"papers_with_a_run_with_no_instrument_failure":0,"papers_where_every_run_was_an_instrument_failure":0,"note":"the per-paper counts of every listed paper (all pages), summed; not a rate"},"key_notes":{"samples_ran_checked":"legacy name, kept unchanged so existing readers do not break: it counts the samples that ran with no instrument failure (honoured, violated, and ran with no contract checked); it does not mean a contract was checked, and the pages print it as 'K with no instrument failure', not 'K checked'","samples_constructed":"a sub-count of the samples that ran, never subtracted from them and never a failure: an executed sample whose run returned an instance of its own class (fixture_out_type equals the entry name): the run built an object and did not compute a result (Syntology's RAN record, counts.constructed)"},"since_archive_judged":{"papers":0,"papers_placed":0,"judged_by":{"model":"a model","models_as_recorded":[],"from":"lb_rows_run_verified.jsonl: each record's `model` field (the extractor's call that wrote decisions[])"},"note":"a model's judgement from the paper's own tables that they report on this leaderboard, not a result: no value from a paper that was not placed is printed or carried here; papers counts each paper once over these leaderboards","backfill":"8,886 of 18,637 newer papers checked so far (733 more had nothing to place; 41 could not be read)","backfill_complete":false,"leaderboards":[]},"papers_note":"The archive never published its papers-using-dataset list; these are papers with a leaderboard row on this dataset's benchmarks.","record_sha256":"41418c23d9134fa6adf1f053c757c53292a9e132c9db50d54f91c03b4d3abaf9","record_changed_at":"2026-10-05","record_changed_at_basis":"changed"}